Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
Subscribe on standards with our subscription service. When you use our service you can be assured the latest editions and easy access.
Read more about SIS Subscriptions
This Part of this European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests which are within the direct field of application of the relevant test method. This part of this European Standard currently cannot be applied to classify curtain walling for resistance to fire. Classification on the basis of extended application is outside the scope of this standard. For extended application, however, the same classes are used as specified in this standard.
This standard deals with:
a) Loadbearing elements without a fire separating function
walls
floors
roofs
beams
columns
balconies
walkways
stairs
b) Loadbearing elements with a fire separating function, with or without glazing, services and fixtures
walls
floors
roofs
raised floors
c) Products and systems for protecting elements or parts of the works
ceilings with no independent fire resistance
fire protective coatings, claddings and screens
d) Non-loadbearing elements or parts of works, with or without glazing, services and fixtures
partitions
facades (curtain walls) and external walls
ceilings with independent fire resistance
fire doors and shutters and their closing devices
smoke control doors
conveyor systems and their closures
penetration seals
linear joint seals
service ducts and shafts
chimneys
e) Wall and ceiling coverings with fire protection ability
f) Lift landing doors which are tested to prEN 81-8 are excluded from this standard. Lift landing doors which are tested to EN 1634-1 are classified in accordance with 7.5.5.