Scope
1.1 This part of ISO 25539 specifes requirements for vascular stents, based upon current medical knowledge. With regard to safety, it gives requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging and information supplied by the manufacturer. It should be considered as a supplement to ISO 14630, which specifes general requirements for the performance of non-active surgical implants.NOTE Due to the variations in the design of implants covered by this part of ISO 25539 and in some cases due to the relatively recent development of some of these implants (e.g. bioabsorbable stents, polymeric stents), acceptable standardized in vitro tests and clinical results are not always available. As further scientifc and clinical data become available, appropriate revision of this part of ISO 25539 will be necessary.1.2 The scope of this part of ISO 25539 includes vascular stents used to treat vascular lesions or stenoses, or other vascular abnormalities. These devices might or might not incorporate surface modifcations of the stent such as drug and/or other coatings. Stents covered with materials that signifcantly modify the permeability of the uncovered stent are within the scope of ISO 25539-1. The stent design might dictate the need to address functional requirements identifed in both ISO 25539-1 and this part of ISO 25539.1.3 Delivery systems are included in this part of ISO 25539 if they comprise an integral component of the deployment of the vascular stent.1.4 Procedures and devices used prior to the introduction of the vascular stent, such as balloon angioplasty devices, are excluded from the scope of this part of ISO 25539.1.5 Some pharmacological aspects of drug-eluting stents are addressed in this part of ISO 25539, but this part of ISO 25539 is not comprehensive with respect to the pharmacological evaluation of drug-eluting stents.

Subjects

Implants for surgery, prosthetics and orthotics (11.040.40)


Buy this standard

Standard Swedish standard · SS-EN ISO 25539-2:2012

Cardiovascular implants - Endovascular devices - Part 2: Vascular stents (ISO 25539-2:2012)
Subscribe on standards - Read more Dölj
Price: 1 731 SEK
standard ikon pdf

PDF

Price: 1 731 SEK
standard ikon

Paper

Price: 2 769,60 SEK
standard ikon pdf + standard ikon

PDF + paper

Show more Show less

Product information

Language: English

Written by: SIS - Hälso- och sjukvård

International title:

Article no: STD-88361

Edition: 3

Approved: 12/17/2012

No of pages: 108

Replaces: SS-EN ISO 25539-2:2009/AC:2011 , SS-EN ISO 25539-2:2009

Replaced by: SS-EN ISO 25539-2:2020