Standard Svensk standard · SS-EN 13463-6:2005

Explosiv atmosfär - Icke elektrisk utrustning för användning i explosionsfarlig atmosfär - Del 6: Övervakning av tändkällor

Status: Upphävd

Köp denna standard

Standard Svensk standard · SS-EN 13463-6:2005

Explosiv atmosfär - Icke elektrisk utrustning för användning i explosionsfarlig atmosfär - Del 6: Övervakning av tändkällor
Prenumerera på standarden - Läs mer Dölj
Pris: 1 013 SEK
standard ikon pdf

PDF

Pris: 1 013 SEK
standard ikon

Papper

Pris: 1 620,80 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ
Omfattning
This document specifies the requirements for the design and construction of equipment, intended for use in potentially explosive atmospheres, protected by the type of protection: Control of ignition source "b".
This document supplements the requirements in EN 13463-1, the contents of which also apply in full to equipment constructed in accordance with this document.
Equipment conforming with the relevant clauses of this document meet the requirements for the following categories:
-- Equipment Group I Category M2 – that does not contain an ignition source arising from severe operating conditions, in particular arising from rough handling and changing environmental conditions in mines;
-- Equipment Group II category 3 – that does not contain an ignition source in normal operation;
-- Equipment Group II category 2G or 2D – that does not contain an ignition source arising as a result of foreseeable malfunctions;
-- Equipment Group II category 1G or 1D – that does not contain an ignition source in normal operation, or under foreseeable malfunctions, or under rare malfunctions.
NOTE The requirements for Group I, Category M1 equipment, are given in EN 50303, which specifies the requirements for both electrical and non-electrical equipment
This type of protection can be used to produce category 3 equipment which otherwise would have an ignition source in normal operation, i.e. it is not able to conform with EN 13463-1
The type of ignition protection described in the standard can be used either on its own or in combination with other types of ignition protection to meet the requirements for equipment of Group I category M2, or Group II categories 1, 2 and 3 depending on the ignition hazard assessment in EN 13463-1.

Ämnesområden

Explosionsskydd (13.230)


Köp denna standard

Standard Svensk standard · SS-EN 13463-6:2005

Explosiv atmosfär - Icke elektrisk utrustning för användning i explosionsfarlig atmosfär - Del 6: Övervakning av tändkällor
Prenumerera på standarden - Läs mer Dölj
Pris: 1 013 SEK
standard ikon pdf

PDF

Pris: 1 013 SEK
standard ikon

Papper

Pris: 1 620,80 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska Svenska

Framtagen av: SIS/SEK ATEX, SIS/TK 001

Internationell titel: Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source 'b'

Artikelnummer: STD-39495

Utgåva: 1

Fastställd: 2005-04-29

Antal sidor: 22