Standard Svensk standard · SS-EN ISO 80601-2-79:2024

Elektrisk utrustning för medicinskt bruk – Del 2-79: Särskilda fordringar beträffande säkerhet och väsentliga prestanda för utrustning för ventilatorer för andningsstöd (ISO 80601-2-79:2024, IDT)

Status: Gällande

Köp denna standard

Standard Svensk standard · SS-EN ISO 80601-2-79:2024

Elektrisk utrustning för medicinskt bruk – Del 2-79: Särskilda fordringar beträffande säkerhet och väsentliga prestanda för utrustning för ventilatorer för andningsstöd (ISO 80601-2-79:2024, IDT)
Prenumerera på standarden - Läs mer Dölj
Pris: 1 731 SEK
standard ikon pdf

PDF

Pris: 1 731 SEK
standard ikon

Papper

Pris: 2 769,60 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ
Provläs denna standard
Omfattning
NOTE 1       There is guidance or rationale for this subclause contained in Clause AA.2.
This document applies to the basic safety and essential performance of ventilatory support equipment, as defined in 201.3.302, for ventilatory impairment, as defined in 201.3.300, hereafter also referred to as ME equipment, in combination with its accessories:
—    intended for use in the home healthcare environment;
NOTE 2       In the home healthcare environment, the supply mains driving the ventilatory support equipment is often not reliable.
NOTE 3       Such ventilatory support equipment can also be used in professional health care facilities.
—    intended for use by a lay operator;
—    intended for use with patients who have ventilatory impairment, the most fragile of these patients, would not likely experience injury with the loss of this artificial ventilation; and
—    not intended for patients who are dependent on artificial ventilation for their immediate life support.
EXAMPLE 1        Patients with mild to moderate chronic obstructive pulmonary disease (COPD).
Ventilatory support equipment is not considered to use a physiologic closed-loop control system unless it uses a physiological patient variable to adjust the artificial ventilation therapy settings.
This document is also applicable to those accessories intended by their manufacturer to be connected to the breathing system of ventilatory support equipment for ventilatory impairment, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory support equipment for ventilatory impairment.
EXAMPLE 2        Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system.
If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant.
Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601‑1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.
NOTE 4       Additional information can be found in IEC 60601‑1:2005+AMD1:2012+AMD2:2020, 4.2.
NOTE 5       See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient. 
This document does not specify the requirements for:
—    ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 80601‑2‑12;
—    ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601‑2‑13;
—    ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601‑2‑84;
—    ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601‑2‑72;
—    ventilatory support equipment or accessories intended for ventilatory insufficiency, which are given in ISO 80601‑2‑80;
—    sleep apnoea therapy ME equipment, which are given in ISO 80601‑2‑70;
—    high-frequency jet ventilators (HFJVs), which are given in ISO 80601‑2‑87;
—    high-frequency oscillatory ventilators (HFOVs);
—    respiratory high flow equipment, which are given in

Ämnesområden

Utrustning för anestesi, respiration och återupplivning (11.040.10)


Köp denna standard

Standard Svensk standard · SS-EN ISO 80601-2-79:2024

Elektrisk utrustning för medicinskt bruk – Del 2-79: Särskilda fordringar beträffande säkerhet och väsentliga prestanda för utrustning för ventilatorer för andningsstöd (ISO 80601-2-79:2024, IDT)
Prenumerera på standarden - Läs mer Dölj
Pris: 1 731 SEK
standard ikon pdf

PDF

Pris: 1 731 SEK
standard ikon

Papper

Pris: 2 769,60 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: Anestesi- och respiratorutrustning, SIS/TK 329

Internationell titel:

Artikelnummer: STD-82091220

Utgåva: 2

Fastställd: 2024-11-06

Antal sidor: 111

Ersätter: SS-EN ISO 80601-2-79:2019